You are in:Home/Publications/Technical Note: Evaluation of a colorimetric point-of-care test for measuring urine ammonium concentration in periparturient dairy cattle

Dr. Ameer A Megahed :: Publications:

Title:
Technical Note: Evaluation of a colorimetric point-of-care test for measuring urine ammonium concentration in periparturient dairy cattle
Authors: AA Megahed; PD Constable
Year: 2020
Keywords: Not Available
Journal: J Dairy Sci
Volume: 103
Issue: 9
Pages: 8655-8660
Publisher: Not Available
Local/International: International
Paper Link:
Full paper Ameer Ahmed Abd-Elhameed Megahed_1-s2.0-S0022030220305476-main.pdf
Supplementary materials Not Available
Abstract:

Urine ammonium concentration ([NH4+]) provides a clinically useful indicator of the magnitude of nutritionally induced systemic acidification in dairy cattle when urine pH < 6.1. The objective of this study was to evaluate the analytical performance of a low-cost point-of-care colorimetric test in measuring urine [NH4+] in dairy cattle consuming an acidogenic ration. A method comparison study was performed using 154 urine samples from 43 periparturient Holstein-Friesian cows. We compared urine [NH4+] measured by an indophenol blue colorimetric test (MColortest, Merck KGaA, Billerica, MA; test method) with levels measured by formaldehyde titration (reference method). Diagnostic performance was evaluated using Pearson correlation coefficient (r), Passing-Bablok regression, Bland-Altman plot, and binary logistic regression. Urine [NH4+] measured by the colorimetric test was strongly correlated (r = 0.98) with urine [NH4+] measured by formaldehyde titration. Method comparison studies indicated that the colorimetric test provided acceptable test performance when urine [NH4+] < 80 mmol/L. Logistic regression analysis indicated that the area under the receiver operating characteristic curve for the colorimetric ammonium test was high at 0.985 when used to identify formaldehyde titration [NH4+] > 10 mmol/L, equivalent to urine pH 11 mmol/L) for the colorimetric test, sensitivity = 0.94, specificity = 0.97, positive likelihood ratio = 27.6, and κ = 0.89, indicating excellent test performance. We conclude that the indophenol blue colorimetric test provided an accurate, low-cost, and practical on-farm test for measuring urine [NH4+] in diluted urine samples from dairy cattle consuming an acidogenic ration.

Google ScholarAcdemia.eduResearch GateLinkedinFacebookTwitterGoogle PlusYoutubeWordpressInstagramMendeleyZoteroEvernoteORCIDScopus