You are in:Home/Publications/Chordae Tendineae Sparing during Mitral Valve Replacement: A Comparative Study

Ass. Lect. Mahmoud Mohammed Abdel Azeem Ahmed Mubarak :: Publications:

Title:
Chordae Tendineae Sparing during Mitral Valve Replacement: A Comparative Study
Authors: Ahmed M Abdelazim, Ashraf Mostafa Elnahas, Yousry Elsaid Rizk, Hany Mohammed Elrakhawy, Mahmoud Mohammed Abdel Azeem Mubarak, Mahmoud Ahmed Al-Shafiey
Year: 2023
Keywords: Not Available
Journal: Not Available
Volume: Not Available
Issue: Not Available
Pages: Not Available
Publisher: Not Available
Local/International: Local
Paper Link: Not Available
Full paper Mahmoud Mohammed Abdel Azeem Ahmed Mubarak_280-Article Text-3532-2-10-20230830.pdf
Supplementary materials Not Available
Abstract:

Background: Mitral valve replacement (MVR) with chordal sparing could improve ventricular function in patients with mitral regurgitation. This study aimed to compare the outcomes of prosthetic MVR with and without chordae tendineae sparing. Methods: This prospective, single-blinded, randomized study was executed on 60 patients undergoing prosthetic MVR with or without chordae tendineae sparing. Patients were divided into two equal groups: Group A (n= 30) included patients who underwent MVR with complete chordae tendineae sparing, and Group B (n= 30) included patients who underwent mitral valve replacement without chordae tendineae sparing. Results: Patients who underwent chordae tendineae sparing demonstrated significantly lower total bypass time (median = 67 vs. 110 min, P < 0.001), total cross-clamp time (median = 40 vs. 80 min, P < 0.001), inotropic support (30% vs. 96.7%, P < 0.001), and arrhythmia (6.7% vs. 86.7%, P < 0.001) than those who did not undergo chordal sparing. Additionally, patients who underwent sparing demonstrated a significantly lower 6-month left ventricle end-systolic diameter (3 ±0.8 vs. 3.9 ±0.5 cm, P < 0.001), 6-month left ventricle end-diastolic diameter (4.4 ±0.7 vs. 5.3 ±0.5 cm, P < 0.001), 3-month left atrium diameter (4.5 ±0.8 vs. 5.1 ±0.6 cm, P < 0.001), and 6-month left atrium diameter (4.3 ±0.8 vs. 5.4 ±0.6 cm, P < 0.001). Conclusion: This technique of MVR might enhance cardiac function and structural parameters and lower the end-diastolic and systolic diameters and the end-systolic and diastolic volumes up to the sixth month of follow-up

Google ScholarAcdemia.eduResearch GateLinkedinFacebookTwitterGoogle PlusYoutubeWordpressInstagramMendeleyZoteroEvernoteORCIDScopus