You are in:Home/Publications/Towards high accuracy measurements for gas flow rate using ultrasonic devices in oil fields

Dr. Reham Samir Saad Ibrahim :: Publications:

Title:
Towards high accuracy measurements for gas flow rate using ultrasonic devices in oil fields
Authors: Waleed Sayed Khadrawy, M. M. Elsherbini, Reham S. Saad, and Hala M. Abd Elkader
Year: 2017
Keywords: USM; Ultrasonic device; Orifice Plate; Flow Measurement
Journal: 13th International Computer Engineering Conference (ICENCO
Volume: Not Available
Issue: Not Available
Pages: 178-183
Publisher: IEEE
Local/International: Local
Paper Link:
Full paper Reham Samir Saad Ibrahim _W_1.pdf
Supplementary materials Not Available
Abstract:

in the last couple of years, ultrasonic meter a device has established and considered the fastest-growing new technologies in the oil and gas fields. The Orifice plate problems are very uncertainty and very high cost in maintained. The Ultrasonic Meters (USMs) have improved in the petroleum career because they provide substantial value to the clients by dropping the cost of doing the commercial. More applications are existence planned today using this technology. The main objectives of the proposing USMs used in Alexandria City (IDKU Site Plant) are to measure gas flow rate in Gas filed which have more benefits over the orifice plate in reducing measurement uncertainty to achieve the high accuracy before export to the domestic grid. The aim of this paper is to compare between USM and Orifice plate via simulation and experimental results.

Google ScholarAcdemia.eduResearch GateLinkedinFacebookTwitterGoogle PlusYoutubeWordpressInstagramMendeleyZoteroEvernoteORCIDScopus