You are in:Home/Publications/The Effect of Irrigation Power and Ureteral Access Sheath Diameter on the Maximal Intra-Pelvic Pressure During Ureteroscopy: In Vivo Experimental Study in a Live Anesthetized Pig

Dr. Yasser Abdelsattar Noureldin :: Publications:

Title:
The Effect of Irrigation Power and Ureteral Access Sheath Diameter on the Maximal Intra-Pelvic Pressure During Ureteroscopy: In Vivo Experimental Study in a Live Anesthetized Pig
Authors: Yasser A Noureldin 1 2 , Panagiotis Kallidonis 1 , Panteleimon Ntasiotis , Constantinos Adamou , Evangelos Zazas , Evangelos N Liatsikos
Year: 2019
Keywords: Not Available
Journal: Journal of Endourology
Volume: 33
Issue: 9
Pages: 725-729
Publisher: Mary Ann Liebert
Local/International: International
Paper Link:
Full paper Not Available
Supplementary materials Not Available
Abstract:

Objectives: To assess the effect of irrigation settings and the size of ureteral access sheath (UAS) on the maximal intra-pelvic pressure (IPPmax) during ureteroscopy (URS) in pigs. Materials and Methods: In supine position, three anesthetized female pigs underwent cystoscopy to insert a 6F ureteral catheter in each ureter. Pigs were then turned to prone position to establish a percutaneous access, insert a 10F nephrostomy tube in the kidney, and connect it to a urodynamic device. An 8F semi-rigid ureteroscope or the Flex-X2 Flexible Ureteroscope was used with two irrigation settings: gravity flow and manual pumping using a commercial pump. URS was performed without UAS and with the UAS 9.5/11, 12/14, 14/16 at the ureteropelvic junction and the IPPmax was recorded. Results: Under gravity irrigation, the recorded IPPmax during semi-rigid URS in the distal ureter and the renal pelvis was 0 and 30 cmH2O, respectively. Further, the IPPmax during flexible URS in the renal pelvis without UAS, with UAS 9.5/11.5, with UAS 12/14, and with UAS 14/16 was 23, 6, 2, and 1 cmH2O, respectively. Under manual pumping, the IPPmax during semi-rigid URS in the distal ureter and the renal pelvis was 84 and 105 cmH2O, respectively. Further, the IPPmax during flexible URS in the renal pelvis without UAS, with UAS 9.5/11.5, with UAS 12/14, and with UAS 14/16 was 45, 46, 18, and 1 cmH2O, respectively. Conclusion: Manual pumping can significantly increase the IPPmax to unsafe levels during URS. The UAS can significantly decrease the IPPmax, even under manual pumping. The larger the UAS, the lower the IPPmax. The use of UAS can render URS safer by acting as a safeguard against the consequences of increased IPP, even under forced irrigation.